Abstract

PurposeAs interventional radiologists, we encounter precarious deep-seated mediastinal lesions in our day-to-day practice. The conventional technique of percutaneous transthoracic biopsy of these lesions carries significant intrinsic complications. Endovascular approaches for such lesions under fluoroscopic guidance have been described in previous literature but with significant technical constraints. In this article, we would like to describe the novel approach of computed tomography (CT)-guided trans superior vena caval biopsy, which we have performed in 3 consecutive precarious mediastinal lesions.Material and methodsWe placed a vascular sheath under ultrasound and fluoroscopic guidance considering the intended angle of needle puncture and length to reach the target lesion from the puncture site. With the sheath in situ, the trans superior vena caval biopsy was performed under CT guidance, and multiple cores of target tissue were safely and successfully obtained.ResultsWe have carefully and successfully employed this novel technique of CT-guided trans superior vena caval approach for 3 tricky deep-seated mediastinal lesions with very low risk of complications.ConclusionsThrough this article, we would like to enhance the importance of thought-provoking new techniques in tackling complex challenging referrals.