Abstract

Abstract The failure of masonry in laboratory testing of walls and prisms and certain aspects of grouted construction is often the result of tensile splitting. These tensile stresses arise from differences in modulus of elasticity and Poisson's ratio between the masonry unit and mortar or grout. Since tensile splitting is so prevalent in masonry construction, a better means of evaluating the tensile strength of masonry units is needed. A splitting tensile test is proposed as a means of measuring tensile strength of masonry units. Splitting strength is compared to standard strength tests for 14 clay units and 14 concrete block units. Uniform failure modes and strengths support the adoption of a splitting test as a standard of masonry unit strength.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.