Abstract

Patients have complained of pain after the use of the central one-third patellar tendon for reconstruction of the anterior cruciate ligament-deficient knee. This study investigated the effect on patellofemoral contact areas and pressures of harvesting the central 10 mm of the patellar tendon in five cadaveric knees. Isometric quadriceps forces were applied to produce approximately 30% of reported maximum voluntary extension moments at the knee. Using Fuji pressure-sensitive film, measurements were recorded for three states: the normal knee, after the graft removal, and after the tendon was closed. Contact areas and pressures were measured at 20 degrees, 30 degrees, 60 degrees, and 80 degrees of knee flexion in each specimen. Tests of the reproducibility of our methods were performed. Average patellofemoral contact areas for three states ranged from 1.6 cm2 at 20 degrees of knee flexion to 3.0 cm2 at 60 degrees. The average patellofemoral contact pressures ranged from 1.9 MPa at 20 degrees of knee flexion to 3.0 MPa at 30 degrees. At each flexion angle there were no significant differences in average patellar contact area or pressure for the three states (P < 0.05). These results suggest that neither harvesting the central 10 mm of the patellar tendon, nor closing the gap, significantly alters patellofemoral contact area or pressure.