Abstract

The efficiency of TSP samplers for large particles is determined by inertial effects; instead of using Stokes number for characterizing the instrument, the particle stop distance is chosen. Polydisperse glass beads with aerodynamic diameters between 20 and 120 μm were used as calibration aerosol. The size distribution sampled under in situ conditions as compared to the original size distribution gives the aspiration efficiency, provided that the smallest particles in the test aerosol are sampled with sufficient efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.