A sensor capable of measuring small shear stresses in wind tunnel applications is presented. The sensor utilizes an in-plane cantilever concept for shear stress measurement, designed to minimize intrusiveness into the airflow and allow easy incorporation into wind tunnel test models. The sensor operates independently of input voltage, and can measure <1 Pa shear stresses with a sensitivity of 8.6 (mV V−1) Pa. Altering the geometry of the sensor has a direct effect on the sensitivity and so can be used to adapt the sensor for different applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.