Abstract

This paper describes a method for the measurement of impulse spectral intensity. An important application of the method is the calibration of impulse generators used for electromagnetic interference measurements and for field strength meter calibration. The measurement equation is derived from Fourier integral analysis of the impulse generator output pulse and the response of a measurement network to the pulse. The confusion surrounding the definition of impulse spectral intensity is reduced by studying the origins of some of the popular definitions. The quantity measured by this method is carefully defined. An impulse generator calibration system utilizing this method in the 150 kHz to 1 GHz range is described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.