Abstract

To address the current stress problem brought on by the auxiliary resonant pole inverter’s pre-charge state, this paper gives an improved auxiliary circuit based on the original inverter. The improved circuit avoids a pre-charge state by adding auxiliary capacitors to form a resonant branch. In contrast to the original inverter, this inverter lowers the current stress on both the auxiliary and primary switches by resolving the pre-charge state’s current stress issue. As a result, the inverter’s losses are decreased, which raises the system’s efficiency. The working principle of this inverter is given in the paper. After a comparison and analysis of the inverter’s pre-charge state, an experiment is used to confirm the device’s viability.

Full Text
Published version (Free)