Abstract

In this paper, an optimized space vector modulation (SVM) method is proposed for the isolated three-phase matrix-type AC/DC converter, where the four-quadrant operation ability of the bidirectional power switch can be fully used. The primary-side transformer current can be eliminated naturally during zero current vectors without extra switching actions. Therefore, the conduction loss of matrix converter (MC) is reduced and the efficiency can be increased. Moreover, the proposed method can avoid the shoot-through operation in MC, and the common-mode voltage can be mitigated effectively. As the zero current vector is kept with the proposed modulation strategy, the current harmonics will not be increased. Thirdly, both the DC-link inductor current and DC-bias current of high-frequency transformer (HFT) are measured through the secondary-side current of HFT. Therefore, the DC-bias current and the saturation of HFT are avoided by closed-loop control with the proposed modulation strategy. The experiments have been carried on a 1-kW laboratory prototype to verify the validity of the proposed modulation scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.