Abstract

This paper presents an interpolation with Backward Euler (BE) method that enhances the switching simulations accuracy in an electromagnetic transient (EMT) simulation with a fixed time-step. Because of the switching operations on discrete instants, the simulations can show artificial voltage spikes and numerical oscillations (chatter), compromising the accuracy and producing misleading results. We thus present a method that eliminates the spurious switching losses and improves the accuracy by combining interpolation and extrapolation with a half-time-step BE solution over existing interpolation-based approaches to resolve the issues above. In addition, this improved method requires the same calculation steps as the industry-accepted instantaneous interpolation. Analytical discussion reinforced by the simulation studies for a simple and complex power electronic circuits demonstrates the accuracy and efficacy of the proposed interpolation with BE method.