Abstract
A novel current injection network for low-harmonic rectifiers that apply the third harmonic current injection is proposed in this paper. The current injection network requires one inductor, two capacitors, and one 1:1 transformer with a voltampere rating of only 0.16% of the input power. The transformer is introduced to provide complete rejection of harmonic components of the injected currents at even triples of the line frequency, resulting in significant reduction of the input current total harmonic distortion (THD). Dependence of the input current THD on the current injection network Q factor is computed. The THD is shown to be in the range 4%<THD<5.125%. Analytically obtained results are experimentally verified on a 1.5 kW rectifier.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.