Abstract
This paper investigates the neutral-point (NP) potential unbalance of the fault tolerant topology of three-level neutral-point-clamped (NPC) inverter, namely the eight-switch three-phase inverter (ESTPI). It is illustrated in this paper that the conventional carrier-based pulse width modulation (CBPWM) will cause the NP potential unbalance of ESTPI. Moreover, the NP potential unbalance will lead to the output voltage unbalance, which seriously deteriorates the system performance of ESTPI. As a consequence, an improved CBPWM, where the upper and lower triangular carriers have different amplitudes, is proposed to guarantee a three-phase balanced output voltage of ESTPI. The simulation results demonstrate that the proposed scheme can suppress the unbalance of three-phase output voltage effectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.