Abstract

The accurate analysis of stable carbon isotope ratios of individual n-alkanes in petroleum by gas chromatography isotope ratio mass spectrometry (GC–irMS) requires that the n-alkanes be separated from branched/cyclic hydrocarbons. Conventional separation methods include urea adduction or separation using different types of molecular sieves (5A, ZSM5). Although the molecular sieves procedures are well established, they generally require the use of hydrofluoric (HF) acid, a potentially hazardous material, to digest and release compounds trapped within the sieve. In this study, a simplified 5A method that avoids the use of HF acid has been developed to isolate n-alkanes ranging from n-C 8 to at least n-C 30 from a saturated petroleum hydrocarbon fraction. 12% cyclohexane in n-pentane was found to be a sufficient solvent in extracting most of the n-alkanes (>90%) in the n-C 8 to n-C 30 range from the sieve. The new 5A sieve procedure is a rapid and safer method for extracting n-alkanes from petroleum to yield fractions amenable for routine GC–irMS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.