Abstract

We present the characterization of a Diamond detector and its response as a beam rate monitor with full stopping of radioactive ion beams of high intensity. The detector has been implemented in the VAMOS focal plane at GANIL and utilised in conjunction with AGATA and MUGAST detector systems. In the present experiment, for the first time, the beam has been fully stopped, rather than being recorded by a transmission detector. The Diamond detector has been tested for use as a particle counter for monitoring a high intensity, radioactive ion beam in the study of the alpha transfer reaction 7Li(15O,t)19Ne. The present experiment, which took place in July 2019, has used a 15O radioactive beam with a high intensity of 107 particles per second due to the weak reaction population and it has been measured using the VAMOS spectrometer and the AGATA and MUGAST arrays. Detailed monitoring of beam intensities in the range of 106 – 107 particles per second is particularly challenging in radioactive ion beam experiments. Thus, the chosen method involves the diamond detector due to its sub-nanosecond response time as well as its radiation hardness. The study of the alpha transfer reaction 7Li(15O,t)19Ne will be performed to determine the radiative alpha capture rate on 15O which is a key breakout route from the Hot-CNO cycle which leads to a explosive nucleosynthesis in X-ray bursts.

Highlights

  • We present the characterization of a Diamond detector and its response as a beam rate monitor with full stopping of radioactive ion beams of high intensity

  • The detector has been implemented in the VAMOS focal plane at GANIL and utilised in conjunction with AGATA and MUGAST detector systems

  • The understanding of X-ray bursts’ mechanisms on neutron star surfaces and the subsequent nucleosynthesis relies on the study of key reactions taking place on them

Read more

Summary

Introduction

The understanding of X-ray bursts’ mechanisms on neutron star surfaces and the subsequent nucleosynthesis relies on the study of key reactions taking place on them. We present the characterization of a Diamond detector and its response as a beam rate monitor with full stopping of radioactive ion beams of high intensity. The Diamond detector has been tested for use as a particle counter for monitoring a high intensity, radioactive ion beam in the study of the alpha transfer reaction 7Li(15O,t)19Ne. The present experiment, which took place in July 2019, has used a 15O radioactive beam with a high intensity of 107 particles per second due to the weak reaction population and it has been measured using the VAMOS spectrometer and the AGATA and MUGAST arrays.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.