Abstract

Verification of protocols is performed through conformance testing. The aim of this paper is to introduce the conformance test generation approach for protocols described by means of Finite State Machines. A functional fault model is adopted and the state discrimination is performed by applying an extended version of Unique Input Output Sequences (UIO), which, different from classical UIO, can always be found in any state. Both algorithms for efficient extended UIO sequence identification and for optimal test sequence generation are presented, together with the experimental results on different protocol descriptions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.