Abstract

An experimental system for automatic visual measurement of surface mount device (SMD) placement on printed circuit boards is described. Infrared illumination is used to aid in segmentation of component lead and solder pad images from the background. Best-fit lines through centroids of the lead and soldering pad images are calculated, from which the displacement and the angular orientation of the component relative to the pads is computed. Measurements are derived from a combination of slope and mean centroids from opposite sides of a device to reduce the effects of sensor resolution, missing pads, or missing leads. Experimental results of testing the accuracy of the system are reported. The results compare favorably with manufacturer's placement tolerance specification and with measurements made manually. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.