Abstract
The work described in this research is concerned mainly with the experimental verification of the effect of boundary layer suction on the diffuser performance having three different divergence angles. The test facility has been designed so as to permit different values of suction velocities (0, 0.386, 4.88 and 6.365 m/sec). The static pressure and total pressure were measured by pitot – static tube and inclined manometer. The application of boundary layer suction was found to increase the pressure recovery and hence increase the diffusion efficiency. An improvement in pressure recovery was found to be more significant for diffuser having divergence angle (15o).The maximum percentage improvement in pressure recovery obtained is (34.7 %). The study of B.L control through its suction leads to better understanding of the flow geometrical design and parameters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.