Abstract

Results from thermal-hydraulic tests of a full-scale module of the emergency cooldown system for a KLT-40S reactor installation are presented. The validity of the solutions adopted in its design is shown. Recommendations for calculating the heat transfer coefficients during steam flow condensation and condensate cooling are given.