Abstract
Top heat loss coefficient (Ut) is required for thermal performance evaluation of a box- type solar cooker. In the present work, the values of Ut were obtained from outdoor experiments undertaken to determine the First Figure of Merit (F1). Ut was found to vary from summer to winter. Acomparison of values of Ut obtained from the experiments with the values obtained from analytical equation showed the same trend. The effect of use of measured value of outer glass cover temperature (T2), or estimated value of T2, on Ut computed by analytical equation was also studied. The measurement of T2 was found to be not essential for obtaining Ut by this equation. As obtaining T2 by experiments also involves uncertainties, one might prefer to use existing correlations for T2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.