Abstract

The purpose of this study is to investigate the freeze-thaw resistance, one of the most important durability indicators, of high-performance concrete made of fibers (nylon and polypropylene), AE agent, viscosity agent, and fly ash, an industrial by-product. While FN-1 showed the best freeze-thaw resistance with an about 2.8% relative dynamic modulus of elasticity, PV-2 showed the worst results, with an about 7.4% modulus, in comparison tests with GC. Most of the test samples showed better compressive strength than GC. Especially, N-1 showed the greatest compressive strength increase of 8%. Also, the test samples mixed with FA and PP showed a 2-4% compressive strength increase effect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have