Abstract

This paper seeks to solve the problem of orthotropic anisotropic steel deck pavement being prone to damage and fatigue, and to study the negative moment performance of steel-ECC concrete composite deck slabs. In this work, four groups of eight specimens were designed for the negative moment four-point bending test study, which included four variables of two ECC slab thicknesses and two bolt spacings. By analyzing the damage mode, crack distribution characteristics, bending load capacity, load-deflection curve, and load-strain curve, the effects of different ECC slab thicknesses and bolt spacings on the bending performance, deformation capacity, and cracking behavior of the steel-ECC composite bridge deck were investigated. The test showed that the combined structure of the ECC and steel plate showed good integrity and good ductility under a negative bending moment, and the damage mode of the member was pure bending of a section of the ECC with concrete cracking damage. When the thickness of the ECC plate increased from 50 mm to 75 mm, the ultimate flexural load capacity of the specimen increased by 92.6%, and when the distance between bolts was reduced from 200 mm to 150 mm, the ultimate flexural load capacity of the specimen increased by 13.4%. The increase in the ECC layer thickness increases the ultimate bearing capacity of the specimen significantly, and the decrease in the bolt spacing increases the ultimate bearing capacity of the specimen less.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call