Abstract

In this study, the factors affecting the occurrence of submerged vortices and their formation mechanism were clarified with reference to flow pattern and vortex position for various dimensions. The experiments indicate that (1) the flow pattern in the proximity of the pump suction bell and the formation pattern of vortices depend on the ratio of bell clearances against the rear and side walls in the sump, (2) submerged vortices are generated on the back wall when the edge of the bell is close to the back wall and occur on the side wall when the bell is located at a larger distance, and (3) critical velocity for vortex occurrence is affected to a great degree by the bottom clearance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.