Abstract

This paper describes a study carried out in the ICITECH laboratories (Universitat Politècnica de València) on RC columns repaired on all four sides with cementitious-based mortars. A total of 18 specimens were tested, representing a group of square 20 × 20 mm2 columns subjected to compressive axial loads. Different repair scenarios were considered in order to study the influence of the type of mortar used and the presence or absence of bonding agents between the mortar and the column concrete. The results obtained showed that bonding agents have no appreciable effect on the behaviour of the repaired columns. Of the two types of mortar used in the study (Classes R3 and R4), the columns repaired with the lower grade mortar (R3) were seen to behave better. The main novelty of this work lies in the fact that this is the first time that two types of mortar are compared in the repair of four column sides, in addition to the possible use of bonding agents between the mortar and the column.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.