Abstract
Experiments were performed with an array of horizontal tubes, arranged in a regular equilateral triangular pattern, immersed in a fluidized bed. Three different bed operating temperatures were used, these being 705, 761 and 812 K. Data are reported for heat transfer between the bed and a centrally-located tube in the array. Both total and radiative heat transfer rates were measured for three different sizes of particles and for superficial velocities spanning the range from packed bed conditions to over twice the minimum fluidization velocity. Local heat transfer values, measured around the tube periphery, and integrated averages are reported for all test conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.