Abstract
In this paper, heat/mass transfer and pressure drop characteristics for arrays of nonuniform plate length, aligned at an angle of 25 deg to the flow direction, are investigated experimentally via a naphthalene sublimation technique. The measurements of cyclic average Sherwood numbers and friction factors in the fully developed regime are conducted for nine geometric configurations. The following parameter ranges are studied: length ratio of successive plates 1.5–2.5; ratio of the transverse pitch to the longitudinal pitch 0.381–0.8, and Reynolds number based on short plate length 1.98×102 to 1.66×103. Comparisons with the results for arrays with uniform plate length are conducted. Two constraints are used, identical pumping power and identical pressure drop. It is found that for most cases studied, the thermal performance of the array with a nonuniform plate length is better than that of the array with a uniform plate length.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.