Abstract

We used a posterior semicircular canal that had been isolated from a frog. From the utricular side the ampulla was cut open at a position one third of the way along the long axis. The cupula was removed through this opening using a glass micropipette. The action potential from the posterior ampullary nerve was recorded before and after removal of the cupula. After removal, the action potential disappeared almost completely. When the cupula was put back on the crista, the action potential was restored. When the cupula was put back upside down, the action potential recovered, but to a lesser extent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.