Abstract
Wall and liquid side heat fluxes near the leading edge of a vertical wall 6.3 cm wide and 10.3 cm high were measured during subcooled film boiling of water at 1 atm pressure. The heat flux from the interface into the liquid and temperature profiles in the liquid thermal layer were measured using real time holographic interferometry. The wall heat flux was measured with thermocouples embedded in a copper block, one face of which served as the heated wall. The role of the leading edge vapor layer, ripples, and large bulges in modifying the liquid side heat transfer is quantified.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.