Abstract

The flow field and the distribution of the flow parameters in the rotating stall regime in a three stage axial flow compressor were obtained in detail using three-hole cylindrical probes containing fast response transducers in association with a digital data acquisition system and an ensemble averaging technique. An appreciable amount of experimental data are presented in this paper with a critical discussion on those.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.