Abstract

Gamma-ray buildup factors for a point isotropic source in stratified spherical shields have been studied experimentally. Energy absorption rates for an experimental setup of iron spheres in water have been measured using the thermoluminescent dosimeter (TLD)-200. The measured absorbed doses in the TLD have been converted to the absorbed doses in iron and water by using cavity ionization theory. The measured absorbed doses and energy absorption buildup factors in iron and water were then compared with those calculated using the BIGGI-4T and EGS4 codes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.