Abstract

Many studies have been carried out on frost distribution and growth and their impacts on the performances of finned tube heat exchangers (FTHXs), the most commonly used structure for the outdoor coils of air source heat pump units. However, in almost all the studies, ethylene glycol water solution was used as refrigerant, which made the investigating of frost distribution and growth difficult due to the uneven temperature distribution along the tube length. Furthermore, quantitative experimental data for the frost distribution and growth on FTHXs have been insufficient. Therefore, in this paper, a quantitative experimental study using R410A as refrigerant on frost distribution and growth on two FTHXs with different fin pitches is reported. The study results demonstrated that the frost accumulated on an FTHX could be divided into two parts, one accumulated on the edge of windward fins and the other on the surfaces of fins and tubes. Furthermore, the ratios of the frost mass accumulated on the edge of windward fins to that on the entire FTHX surface were 13.7% (60 min frosting duration) and 12.5% (120 min frosting duration) for the two FTHXs, respectively. The frost thickness and average frost densities in these two parts were also evaluated and compared.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.