Abstract
An experimental study of the free convection heat transfer between the cylindrical absorber and the flat top of a compound parabolic concentrator (CPC) is described. Results are obtained for a range of absorber temperatures and four CPC cavity heights. For similar conditions of operating temperature, the heat transfer from a cylinder in free air is about 30 to 50 percent higher than in a CPC cavity. Two correlations for Nusselt and Grashof numbers have been obtained using the equivalent length and the cavity height as the characteristic length of the system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.