Abstract

Junction flow loss is one of the sources of flow losses in many engineering pipe systems. An experimental study was carried out in order to investigate the combining steady pressure loss coefficients at 45° T-junctions with three area ratios between lateral branch and main duct. Extensive measurement data were obtained at a wide range of Mach number (0.1–0.6) and mass flow rate ratios using air as the tested fluid. Comparative analysis of the results includes the pressure difference in the two flow paths of the junction, the effect of Mach number in common branch due to gas compressibility, as well as the loss coefficients with various geometry condition. The following conclusion is drawn: the total pressure loss coefficient ( K) was mainly dependent on the Mach number ( M3), mass flow rate ratio ( q), and area ratio ( a), while almost independent on Reynolds number. The results provide reference for the research of junction flow and can be valuable in the correction of the boundary condition in one-dimensional simulation models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.