Abstract

Composite Truss has several benefits such as rapid construction and low span/depth ratio and is a competitive structure shape of span length having 12m to 18m. However, developed countries become aware that additional research is needed to analyze fire behavior for tall buildings after the September 11th attacks. This research is conducted to carry the experimental study of fire behavior of composite truss which was used in the World Trade Center. This study examined thermal resistance behavior of the composite truss system. The following conclusions were obtained based on the results of the tests. As the loading stress decreased, the specimens took more time in reaching their structural deflection limits. Truss-sheathing was found to contribute to lower temperature increases as well as higher thermal resistance. Deflection of the composite truss system took place with varying degrees depending on loading ratio. Thermal-resistant sheathing, however, was found to delay the deflection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.