Abstract

In this work, the entire pool boiling curve of tetrafluoromethane (R14) under 0.1 MPa was experimentally acquired on a horizontal copper surface, and the nucleate boiling, critical heat flux (CHF) point, transition boiling, Leidenfrost point (the minimum film boiling point) and film boiling were observed. In the nucleate boiling regime, boiling heat transfer data and bubble images depicting the boiling behavior at different heat fluxes were obtained from the measurements. The measured heat flux at the CHF point is 220.39 kW m−2, and the corresponding surface superheat temperature is 16.1 K. The measured CHF data were also compared to several existing correlations, including the Bailey and Lienhard & Dhir correlations, both of which show good agreement. We also measured the boiling heat transfer data in the transition and film boiling regimes. The measured heat flux and surface superheat temperature of the Leidenfrost point were 126.83 kW m−2 and 87.1 K, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.