Abstract

A set of condensation experiments in the steam–air and pure steam conditions has been conducted to evaluate the heat removal capacity of a vertically pin-fin tube under free convection. Condensation heat transfer coefficient and heat transfer rate have been obtained. The bulk temperature, wall temperature and temperature near tube surface are measured in detail. As a reference, a smooth tube is tested under the same condition. For pure steam case, the pin-fin tube generates restrictions on the condensation heat transfer process in low wall subcooling region. With a higher wall subcooling, the pin-fin tube shows a larger condensation heat transfer coefficient than smooth tube does. For steam–air mixtures case, the result of the temperature measurement demonstrates that there is an air rich region near the pin-fin tube. Compared with the smooth tube, the pin-fin tube generates reduction effect on the condensation heat transfer process under low air mass fraction situation. As air mass fraction increasing, the condensation heat transfer coefficient of the pin-fin tube becomes larger than that of the smooth tube.