Abstract

Experiments on subcooled and saturated pool boiling of ethanol are conducted on horizontal heated surfaces with micro- and nano-sized structures. The effects of structure size on bubble nucleation and departure characteristics as well as the heat transfer coefficient are discussed. It is found that microstructures can enhance bubble nucleation by significantly increasing the active nucleation site density at low heat fluxes, thus reducing the wall superheat and enhancing heat flux; while nano-structures can accelerate bubble departure by decreasing bubble departure diameter and increasing departure frequency. On the other hand, nano-structures will delay bubble mergence and prevent the vapor film from spreading at high heat fluxes during boiling crisis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.