Abstract

This paper investigates the feasibility of monitoring progressive delamination growth in Z-pinned composite laminates via the measurement of through-thickness electrical resistance. This novel health monitoring technique is based on connecting Z-pins both in series and in parallel by means of arrays of electrodes arranged on the laminate surfaces. This creates a multi-functional (through-thickness reinforcing and sensing) laminated structure. Experimental results on double-cantilever beam coupons demonstrate that the entire Mode I bridging response of Z-pins can be monitored, from the arrival of the delamination front to the complete pull-out of the through-thickness reinforcement. Hence the extent of delamination can be inferred from the through-thickness resistance. This is proved for both conductive (carbon fibre-reinforced) and non-conductive (glass fibre-reinforced) laminates. The premature Z-pin failure during progressive pull-out corresponds to an abrupt increase of through-thickness electrical resistance. The delamination sensing/suppression method presented in this paper can be readily applied to Z-pinned composites at structural level.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.