Abstract

The main objective of this paper is to present and discuss failure mechanism, failure mode, as well as plastic deformation of a lattice telecommunication tower obtained during a full-scale pushover test. The manuscript consists of a detailed description of the tested structure and the experimental site. Displacements of particular nodes of the tower are presented as a function of the external load. The main conclusion is that the rigidity of joints between particular elements, which depends on thickness and diameter of connecting flanges and number and quality of bolts, determines the failure mode of the compressed tower legs. In the article, values of axial forces under compression, taken directly from the conducted test, were compared with the standard buckling resistance. On the basis of this comparison, discussion about the effective slenderness factor has been generated, and the proper determination of this coefficient has been proposed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call