Abstract

This paper presents a novel single-phase modified Vienna rectifier (MVR) for the harmonic mitigation and power factor improvement of an induction heating (IH) system. The latter employs a high-frequency resonant inverter that is responsible for the generation of high-frequency harmonics, which, in turn, deteriorates the power quality. This mitigation must be done in accordance with harmonic regulations such as IEEE Std. 519-2014,IEC-555, and EN 61000-3-2, etc. Consequently, an MVR is placed between the power supply and the IH system. The proposed novel MVR topology overcomes the limitations of conventional Vienna rectifiers, such as their unbalanced voltage across output capacitors, high ripple at the output DC bus, and high THD in the supply current, etc. The efficacy of the proposed model has been verified by a series of simulations in PSIM. It is followed by a hardware validation using an Arduino Uno ATmega328 digital controller on a 1.2 kW experimental prototype of the IH system. The simulation and experimental results of the power quality indices comply with the IEEE-519 standards.