Abstract

Measurements are reported of X-ray photoelectron spectroscopy (XPS) investigations, performed under conditions of ultrahigh vacuum, of several metal oxides either produced commercially (high purity) or prepared in the laboratory. The same oxides were also subjected to electrochemical measurements in aqueous solutions for the determination of the point of zero charge (PZC) values and/or the isoelectric points (IEPs). The PZC (IEP) values appear to be linearly correlated with the sum of the metal and oxygen XPS chemical shifts (DM + DO). The higher (more alkaline) the PZC (IEP), the lower the XPS (DM + DO) term and vice versa. The weighting of the different components in the accuracy of the correlation is discussed. It is shown how a cross comparison between experimental XPS and electrochemical data obtained for the same samples can be used as a diagnostic criterion for the occurrence of secondary phenomena at the solid/liquid boundary.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.