Abstract
Air ingress measurements using the 1/20th-scaled Helium Air Ingress gas Reactor Experiment (HAIRE) facility show key geometric variables of interest and their effect on air ingress in small- and medium-sized breaks in High Temperature Gas cooled Reactors. These variables include but are not limited to break diameter, break angle, and break wall thickness. Differing wall thicknesses for the same break diameter can have order-of-magnitude changes to the air ingress rate, which is a key figure of merit in the air ingress accident scenario. Additionally, different break sizes can change the importance of the angle in the break scenario. With smaller breaks, the flow will not transition from intermittent flow, to countercurrent flow, to diffusive flow as the break rotates from vertically upward toward vertically downward. This would lead to less variability with smaller breaks, which in turn would make the accident scenario more predictable for smaller-sized breaks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.