Abstract

Monitoring humidity downstream to conditioning facilities and during transportation is essential for avoiding hydrate deposition. However, water inline monitoring under high pressure is still challenging in the CCS industry. This study presents an experimental and modelling investigation for enhancing field monitoring and model predictions. Measurements are performed using the Differential Scanning Hygrometry (DSH). This novel analytical approach has been successfully tested for measuring dew/frost temperatures for carbon dioxide, CH4+CO2, and CO2-rich mixtures in equilibrium with hydrates, free water and ice. Moreover, the DSH method has been applied for direct HP equilibrium temperature measurements. Also, this work compares three modified versions of the classical SRK EoS with the Multi-Fluid Helmholtz Energy Approximation (MFHEA). This evaluation includes Huron-Vidal and the EMS mixing rules and the cubic-plus association (CPA) approach. A thorough fitting process was carried out and, overall, comparisons with the experimental data showed that SRK + EMS yielded results as satisfactory as sCPA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.