Abstract

A novel photovoltaic-Trombe wall (PV-TW) is proposed and investigated experimentally and theoretically in this paper. The PV-TW was installed at the south-facing external wall of an environmental chamber that carried two identical test rooms. Both of the test rooms have a double window of the same size. One test room was installed with the PV-TW (known as the PV-TW room), and the other without PV-TW (known as the reference room). The influence of the PV-TW on the thermal environment of the test room was investigated under different operating conditions. The experimental results show the dual benefits of the PV-TW system: improving the room thermal condition and at the same time generating electricity. Compared with the reference room, the maximum indoor temperature was found to be 5–7°C higher in winter, and the daily electrical output reached about 0.3 kWh with a PV cell area of 0.72 m2. Also, a detailed model is given to evaluate the performance of PV-TW theoretically, and the PV-TW room is simulated under one certain operating condition. The simulated and measured air temperatures of PV-TW room are found to be in good agreement. Copyright © 2007 John Wiley & Sons, Ltd.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.