Abstract

Reliable laboratory testing is important to detect Toxoplasma gondii infection and focuses on improving the low cost and easy to use the diagnostic instrument. Enzyme-linked immunosorbent assay (ELISA) method can be used to determine a large number of samples within a short period of time which based on antibody or antigen detection. We tested the sensitivity and specificity of GRA1 protein of as antigen using the ELISA method to toxoplasmosis diagnosis and compared it with commercial ELISA kit. Seventy sera samples were collected and tested using indirect ELISA, commercial ELISA kit and GRA1 protein-coated as antigen. The results showed 48 and 51 samples had positive IgG antibody using ELISA-GRA1 and commercial ELISA kit, respectively. The GRA1 sensitivity and specificity on ELISA were 100% and 86.36%, respectively. Whereas positive predictive value (PPV) was 94.11%. This result indicated that the recombinant GRA1 protein is a highly immunogenic protein in human toxoplasmosis and marker for toxoplasmosis screening.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.