Abstract
Between 2005 and 2017, the number of closed reduction and internal fixation of pelvic ring injuries increased by 1116%. Percutaneous fixation is currently the only minimally invasive technique that can stabilize the posterior elements of the pelvis. The purpose of this study was to investigate the utility of the inlet obturator oblique view (IOO) with the hypothesis that the IOO view will improve the accuracy of sacroiliac and transsacral screw placement in the S1 or S2 body and improve the accuracy of assessing whether the implant is fully seated against the outer cortex of the ilium. Ten male pelvic training models were used. Thirty-six screw configurations were inserted by a fellowship trained orthopedic trauma surgeon in appropriately and inappropriately placed sacroiliac and transsacral screw configurations. These configurations were imaged using fluoroscopy in different planes and saved for survey. Fourteen orthopedic professionals reviewed 313 fluoroscopic images. Interrater reliability demonstrated marked improvement in assessment of whether the screw head was seated against the outer cortex of the ilium with the IOO view (kappa = 0.841, without IOO kappa = 0.027). There was a statistically significant difference in overall accuracy (p value < 0.001, OR = 1.57, 95% CI = 1.35-1.84) and whether the screw head was seated (p value < 0.001, OR = 8.14, 95% CI = 5.52-11.99) when compared with and without the IOO view (accuracy with IOO view: 85%, accuracy without IOO view: 78.26%; screw seated with IOO view: 93.93%, screw seated without IOO view: 65.54%). There was no significant difference (p value 0.465, OR = 1.13, 95% CI = 0.82-1.55) determining if the screw was in a safe position (safe with IOO view: 84.64%, safe without IOO view: 83.04%). Our findings demonstrate that misinterpretation of sacroiliac and transsacral screw placement can occur with the standard fluoroscopic imaging. We suggest the addition of the IOO view increases the overall accuracy of screw placement and whether the screw head is fully seated against the outer table of the ilium. This in turn can improve fixation and potentially improve patient outcomes and decrease adverse events.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.