Abstract

The characteristics of an organic Rankin cycle designed to operate with a low temperature geothermal source and constant temperature cooling water supplied from freshwater ponds typical to those found near Waddan City in the Al Jufrah region of Libya were examined. Two working fluids were examined and it was concluded that the most suitable for this application was R-245fa. The off design performance of the organic Rankine cycle was examined and it was shown that the cycle is controlled by the performance of the condenser which is cooling water side temperature limited.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.