Abstract
Objectives. This crossover pilot study aimed to compare the physical load response of an ergonomically improved welding torch versus a conventional torch. Methods. Ten inexperienced volunteers performed an experimental augmented virtual welding trial at chest height (ASME code 1G) and overhead (ASME code 4G) with both welding torches in random order. Skeletal muscle load and fatigue were assessed by surface electromyography and changes in isometric peak force. The sensation of pain, perceived exertion and welding execution quality were defined as further outcome parameters. Results. The muscle load response in three out of eight muscles was lower in favour of the ergonomic welding torch, which went along with a lower sensation of pain and a higher working accuracy. Conclusions. An ergonomically improved welding torch reduces the acute physical load response and sensation of pain, which ultimately allows performing better, and might contribute to prevention of musculoskeletal diseases in the long term.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Occupational Safety and Ergonomics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.