Abstract

This paper concerns the influence of moving an auxiliary limiting cylinder in X-Y directions on the electrostatic field and corona onset voltage of the dual electrode system employed in the electrostatic filtration process resulting in a “Tri-electrode” system. The Tri-electrode system is applied in order to control the field around the ionized wire and on the ground plate. Accurate calculation of the electrostatic field is obtained using the charge simulation method coupled with genetic algorithms. The calculated field values are utilized in computing the corona onset voltage of the ionized electrode. Laboratory measurements of the onset voltage of the ionized electrode are applied. It is found that the limiting cylinder controls the onset voltage of the ionized wire such that the ionized wire may be in ionized or non-ionized state without changing the position of the ionized wire itself. The numerical onset voltage values agreed satisfactorily with those measured experimentally.