Abstract

Rabbit antiserum, specific for protein A from Staphylococcus aureus, was conjugated to alkaline phosphatase and used in a double antibody solid-phase enzyme immunoassay. The assay was developed to monitor eluate from a large-scale protein A-Sepharose affinity column used to purify monoclonal antibodies for human clinical trials. The assay detected soluble protein A in the presence of immunoglobulin at concentrations as low as 4 ng/ml. Analysis of the product purified by affinity chromatography revealed the presence of protein A at ng/ml concentrations. The assay developed here can provide a reliable and convenient method for detecting soluble protein A.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call