Abstract
An enzyme-linked immunosorbent assay (ELISA) for total antibodies to Toxoplasma gondii was modified to measure specific immunoglobulin M (IgM) antibodies. The assay requires three incubation periods totaling 2 h and enzyme-labeled-heavy-chain-specific antibodies to human IgM. The objective read-out in absorbance was normalized to percent of a standardized positive control for interpretations. No difference was observed between the assay results with or without previous absorption of the samples by Staphylococcus aureus protein A to remove most of the IgG antibodies. Addition of serum containing very high levels of IgG antibodies to another containing both IgG and IgM antibodies did not change the IgM assay values for the latter. None of the 22 sera containing high levels of IgM rheumatoid factor (RF) gave positive ELISA IgM results, even though 8 of them also had high levels of IgG toxoplasma antibodies. Mixtures of sera containing high concentrations of RF with sera having high levels of IgG toxoplasma antibodies also failed to show any false-positive reactions in the IgM toxoplasma assay. Thus, this ELISA for T. gondii IgM antibodies was not affected by IgG toxoplasma antibodies and RF.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.