Abstract

Unsafe electrical appliances can be hazardous to humans and can cause electrical fires if not monitored, analyzed, and controlled. The purpose of this study is to monitor the system’s condition, including the electrical properties of the appliances, and to diagnose fault conditions without deploying sensors on individual appliances and analyzing individual sensor data. Using historical data and an acceptable range of normal and leakage currents, we proposed a hybrid model based on multiclass support vector machines (MSVM) integrated with a rule-based classifier (RBC) to determine the changes in leakage currents caused by installed devices at a certain moment. For this, we developed a sensor-based monitoring device with long-range communication to store real-time data in a cloud database. In the modeling process, RBC algorithm is used to diagnose the constructed device fault and overcurrent fault where MSVM is applied for detecting leakage current fault. To conduct an operational field test, the developed device was integrated into some houses. The results demonstrate the effectiveness of the proposed system in terms of electrical safety monitoring and detection. All the collected data were stored in a structured database that could be remotely accessed through the Internet.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call